[1]梁才雄,苏之盟,钟远鸣.椎体成形术骨水泥渗漏防治现状[J].大众科技,2020,22(02):68-71.
 Current Status of Prevention and Treatment of Cement Leakage in Vertebroplasty[J].Popular Science & Technology,2020,22(02):68-71.
点击复制

椎体成形术骨水泥渗漏防治现状()
分享到:

《大众科技》[ISSN:1008-1151/CN:45-1235/N]

卷:
22
期数:
2020年02
页码:
68-71
栏目:
医药与卫生
出版日期:
2020-02-20

文章信息/Info

Title:
Current Status of Prevention and Treatment of Cement Leakage in Vertebroplasty
作者:
梁才雄1 苏之盟 1 钟远鸣 2
(1.广西灵山县中医医院,广西 灵山 530001;2.广西中医药大学第一附属医院,广西 南宁 530023)
关键词:
椎体成形术骨水泥渗漏预防和治疗
Keywords:
vertebroplasty bone cement leakage prevention and treatment
文献标志码:
A
摘要:
经皮椎体成形术(percutaneous vertebroplasty, PVP)是治疗 Kümmell 病、脊柱肿瘤、骨质疏松性椎体压缩性骨折(osteoporotic vertebral compression fractures, OVCFs)等疾病的一项安全有效的微创技术,深受患者和术者的认可,但随着该技术的广泛开展,骨水泥渗漏等并发症引起了临床医生的重视。文章通过检索有关文献加以分析总结,对椎体成形术骨水泥渗漏防治的现状进行综述。
Abstract:
Percutaneous vertebroplasty (PVP) is a safe and effective minimally invasive technique for the treatment of Kümmelldisease, spinal tumor, osteoporotic vertebral compression fractures (OVCFs) and other diseases, and it is recognized by patients andSurgeons. However, with the extensive development of this technology, complications such as cement leakage have attracted the attentionof clinicians. This paper summarizes the status of prevention and treatment of cement leakage in vertebroplasty by searching relevantliterature.

参考文献/References:

[1] Gonschorek O, Hauck S, Wei?T, et al. Percutaneousvertebral augmentation in fragility fractures-indications andlimitations[J]. European Journal of Trauma & EmergencySurgery, 2017, 43(1): 9-17.[2] Zhang G Q, Gao Y Z, Chen S L, et al. Comparison ofpercutaneous vertebroplasty and percutaneous kyphoplastyfor the management of Kümmell’s disease:A retrospectivestudy[J]. Indian Journal of Orthopaedics, 2015, 49(6):577-582.[3] Jamjoom B, Patel S, Bommireddy R, et al. Impact of thequantity of intradiscal cement leak on the progression ofintervertebral disc degeneration[J]. The Annals of TheRoyal College of Surgeons of England, 2017, 99(7):529-533.[4] Tome-Bermejo F, Alvarez L, Pinera A R, et al. Identificationof risk factors for the occurrence of cement leakage duringpercutaneous vertebroplasty for painful osteoporotic or- 71 -malignant vertebral fracture[J]. The Spine Journal, 2013,13(9): S90.[5] Zhan Y, Jiang J, Liao H, et al. Risk factors for cementleakage after vertebroplasty or kyphoplasty: A meta-analysis of published evidence[J]. World Neurosurgery,2017(101): 633-642.[6] Liu X W, Jin P, Wang L J, et al. Vertebroplasty in thetreatment of symptomatic vertebral haemangiomas withoutneurological deficit[J]. European Radiology, 2013, 23(9):2575-2581.[7] Ha K Y, Min C K, Seo J Y, et al. Bone cement augmentationprocedures for spinal pathologic fractures by multiplemyeloma[J]. Journal of Korean Medical Science, 2015,30(1): 88-94.[8] Burgard C A, Julien D, Frederik S, et al. CT fluoroscopy-guided percutaneous osteoplasty with or withoutradiofrequency ablation in the treatment of painfulextraspinal and spinal bone metastases:technical outcomeand complications in 29 patients[J]. Diagnostic andInterventional Radiology, 2018, 24(3): 158-165.[9] Laredo J D, Hamze B. Complications of percutaneousvertebroplasty and their prevention[J]. Seminars inUltrasound, 2004, 33(9): 493-505.[10] Hong S J, Lee S, Yoon J S,et al. Analysis of intradiscalcement leakage during percutaneous vertebroplasty:multivariate study of risk factors emphasizing preoperativeMR findings[J]. Journal of Neuroradiology, 2014, 41(3):195-201.[11] Li S, Wang C, Shan Z, et al. Trabecular microstructure anddamage affect cement leakage from the basivertebralforamen during vertebral augmentation[J]. Spine (Phila Pa1976), 2017, 42(16): E939-E948.[12] Zhang Z F, Huang H, Chen S, et al. Comparison of high- andlow-viscosity cement in the treatment of vertebralcompression fractures: a systematic review and meta-analysis[J]. Medicine, 2018, 97(12): e0184.[13] Wang Y, Huang F, Chen L, et al. Clinical measurement ofintravertebral pressure during vertebroplasty andkyphoplasty[J]. Pain Physician, 2013, 16(4): E411-E418.[14] Gao C, Zong M, Wang W T, et al. Analysis of risk factorscausing short-term cement leakages and long-termcomplications after percutaneous kyphoplasty forosteoporotic vertebral compression fractures[J]. ActaRadiologica, 2018, 59(5): 577-585.[15] Mansour A, Abdel-Razeq N, Abuali H, et al. Cementpulmonary embolism as a complication of percutaneousvertebroplasty in cancer patients[J]. Cancer Imaging, 2018,18(1): 5.[16] Ding J, Zhang Q, Zhu J, et al. Risk factors for predictingcement leakage following percutaneous vertebroplasty forosteoporotic vertebral compression fractures[J]. EuropeanSpine Journal, 2016, 25(11): 3411-3417.[17] Katsanos K, Sabharwal T, Adam A. Percutaneouscementoplasty[J]. Seminars in Interventional Radiology.2010, 27(2): 137-147.[18] Young C, Munk P L,Heran M K, et al. Treatment of severevertebral body compression fractures with percutaneousvertebroplasty[J]. Skeletal Radiology, 2011, 40(12): 1531-1536.[19] Nieuwenhuijse M J, Van Erkel A R, Dijkstra P D S.Percutaneous vertebroplasty in very severe osteoporoticvertebral compression fractures:feasible and beneficial[J].Journal of Vascular & Interventional Radiology, 2011,22(7): 1017-1023.[20] Anselmetti G C, Bonaldi G, Carpeggiani P, et al. Vertebralaugmentation: 7 years experience[J]. Acta NeurochirurgicaSupplementum, 2011, 108: 147-161.[21] Ahlhelm F, Omidi R. Kyphoplasty and vertebroplasty forspinal trauma[J]. Radiologe, 2016, 56(8): 691-697.[22] Kaso G, Horvath Z, Szenohradszky K, et al. Comparison ofCT characteristics of extravertebral cement leakages aftervertebroplasty performed by different navigation andinjection techniques[J]. Acta Neurochirurgica, 2008, 150(7):677-683.[23] Hoppe S, Wangler S, Aghayev E, et al. Reduction of cementleakage by sequential PMMA application in avertebroplasty model[J]. European Spine Journal, 2016,25(11): 1-6.[24] Li J, Li T, Ma Q, et al. Using side-opening injectioncannulas to prevent cement leakage in percutaneousvertebroplasty for osteoporotic vertebral compressionfractures, does it really work[J]. J Orthop Sci, 2017, 22(5):811-815.[25] Sun H B, Jing X S, Liu Y Z, et al. The optimal volumefraction in percutaneous vertebroplasty evaluated by painrelief, cement dispersion, and cement leakage: Aprospective cohort study of 130 patients with painfulosteoporotic vertebral compression fracture in thethoracolumbar vertebra[J]. World Neurosurg, 2018, 114:e677-e688.[26] Wang H, Sribastav S S, Ye F, et al. Comparison ofpercutaneous vertebroplasty and balloon kyphoplasty forthe treatment of single level vertebral compressionfractures: A meta-analysis of the literature[J]. Painphysician, 2015, 18(3): 209-222.[27] Li Y Y, Huang T J, Cheng C C, et al. A comparison betweenone-and two-fluoroscopic techniques in percutaneousvertebroplasty[J]. BMC Musculoskelet Disord, 2008, 9: 67.[28] Do H M.Intraosseous venography during percutaneousvertebroplasty: is it needed[J]. AJNR Am J Neuroradiol,2002, 23(4): 508-509.[29] Yang D H, Cho K H, Chung Y S, et al. Effect ofvertebroplasty with bone filler device and comparisonwith balloon kyphoplasty[J]. Eur Spine J, 2014, 23(12):2718-2725.[30] Zhang L, Wang J, Feng X, et al. A comparison of highviscosity bone cement and low viscosity bone cementvertebroplasty for severe osteoporotic vertebralcompression fractures[J]. Clin Neurol Neurosurg, 2015,129: 10-16.[31] Chen L, Su I C, Ni C F, et al. Percutaneous vertebroplastyperformed with an 18-gauge needle for treatment ofmetastatic severe compression fracture of the cervicalvertebral body[J]. J Vasc Interv Radiol, 2014, 25(9): 1413-1417.[32] Alsaimi S, Capei C, CheninL, et al. Robot-assistedintravertebral augmentation corrects local kyphosis moreeffectively than a conventional fluoroscopy-guidedtechnique[J]. J Neurosurg Spine, 2018: 1-7.[33] Boger A, Wheeler K D, Schenk B, et al. Clinicalinvestigations of polymethylmethacrylate cement viscosityduring vertebroplasty and related in vitro measurements[J].Eur Spine J, 2009, 18(9): 1272-1278.[34] Grelat M, Le Van T, Fahed E, et al. Rare Complication ofPercutaneous Technique:Intradural Cement Leakage and ItsSurgical Treatment[J]. World Neurosurg, 2018, 118: 97.[35] Hatzantonis C, Czyz M, Pyzik R, et al. Intracardiac bonecement embolism as a complication of vertebroplasty:management strategy[J]. Eur Spine J, 2017, 26(12): 3199-3205.[36] Ignacio JMF, Ignacio KHD. Pulmonary Embolism fromCement Augmentation of the Vertebral Body[J]. AsianSpine J, 2018, 12(2): 380-387.

相似文献/References:

[1]王义青 张家立.微创治疗骨质疏松性椎体压缩骨折的进展[J].大众科技,2023,25(10):86.
 Advances in Minimally Invasive Treatment of Osteoporotic Vertebral Compression Fracture[J].Popular Science & Technology,2023,25(02):86.

备注/Memo

备注/Memo:
【收稿日期】2019-12-09【基金项目】国家自然科学资金项目(81760874)。【作者简介】梁才雄(1962-),男,广西灵山县中医医院副院长,研究方向为骨外科。【通信作者】苏之盟(1988—),男,广西灵山县中医医院主治医师,研究方向为骨外科。
更新日期/Last Update: 2020-05-22