[1]常 青 贾力博 林秋莲 向辉云.某 DR 机房整改前后周围环境辐射监测及分析[J].大众科技,2019,21(03):14-15.
 Monitoring and Analysis of Ambient Radiation Before and AfterRectification of a DR Machine Room[J].Popular Science & Technology,2019,21(03):14-15.
点击复制

某 DR 机房整改前后周围环境辐射监测及分析()
分享到:

《大众科技》[ISSN:1008-1151/CN:45-1235/N]

卷:
21
期数:
2019年03
页码:
14-15
栏目:
资源与环境
出版日期:
2019-03-20

文章信息/Info

Title:
Monitoring and Analysis of Ambient Radiation Before and AfterRectification of a DR Machine Room
作者:
常 青 贾力博 林秋莲 向辉云
(广西壮族自治区辐射环境监督管理站,广西 南宁 530222)
关键词:
DR 机房X 射线监控辐射防护
Keywords:
DR machine room x-ray monitoring radiation protection
文献标志码:
A
摘要:
文章通过综合分析某 DR(digital radiography)机房外辐射剂量率异常的原因,提出整改建议,并对整改前后机房周围辐射环境开展监测与评价,同时对实际工作中一些问题展开讨论,旨在为医学诊断 X 射线机项目建设及监管提供借鉴。
Abstract:
In this paper the causes of abnormal radiation dose rate outside a DR (digital radiography) machine room wascomprehensively analyzed, the rectification suggestions were put forward, the radiation environment around the DR machine roombefore and after rectification was monitored and evaluated, and some problems in practical work were discussed, aiming to providereference for the construction and supervision of medical diagnostic X-ray machine projects.

参考文献/References:

[1] 潘自强.电离辐射环境监测与评价[M].北京:原子能出版社,2007.[2] GBZ130-2013.医用 X 射线诊断放射防护要求[S].北京:中华人民共和国国家卫生和计划生育委员会,2013.[3] 欧向明.常用辐射防护仪器电路时间常数的研究[J].中国医学装备,2010,7(2):6-8.[4] 陈峰,何韦川,黄仲明.几种常用辐射探测器对医用 X 射线防护监测适用性的讨论[J].中国辐射卫生,2010,19(1):80,84.

备注/Memo

备注/Memo:
【收稿日期】2019-01-09【作者简介】常青(1990-),女,广西壮族自治区辐射环境监督管理站助理工程师,从事辐射环境监测及评价工作。